You need:
- Computer
- PCB where you want to do change the radio access technology
- mini USB Cable (to connect the PCB to the computer)
- PI Service Terminal
To download the PI Service Terminal for Windows, click on the link below
For more information or help please read Download PI Service Terminal in our solutions.
To change the the RADIO ACCESS TECHNOLOGY see the following steps:
For stations with firmware version 3.18 and older please follow this process:
- Start the PI Service terminal program.
- Connect the PC and the motherboard (PCB) with the USB cable (yellow square below).
- Connect the battery to the main board (red square below)
- Select the correct Serial Port an click on "Connect"
If it is the only one device connected to your PC, COM port is detected automatically. When connecting for the first time, the PC installs the driver for the board (internet connection of the PC required) - Press H to open the MAIN MENU
- To see the Radio Access Technology
press - (P) Setup NBIoT module parameters (blue dart)
Here you see the current Radio Access Technology (pink square)
to change it
press - (8) RADIO ACCESS TECHNOLOGY (yellow dart)
now you can select your Radio Access Technology
select - (1) NB1
or (2) CAT-M1
or (3) GSM
- In this case we selected (1) NB1 (orange dart)
- New radio Access technology is now selected (red square) - to return to MAIN MENU press ECS or press Disconnect and unplug the USB cable.
- Done with setting radio access technology.
For stations with firmware version 3.19 please follow this process:
- Start the PI Service terminal program.
- Connect the PC and the motherboard (PCB) with the USB cable (yellow square below).
- Connect the battery to the main board (red square below)
- Select the correct Serial Port an click on "Connect"
If it is the only one device connected to your PC, COM port is detected automatically. When connecting for the first time, the PC installs the driver for the board (internet connection of the PC required) - Press H to open the MAIN MENU
- To see the Radio Access Technology
press - (P) Setup modem parameters (blue dart)
Here you see the current Radio Access Technology (violett square)
to change it
press - (8) RADIO ACCESS TECHNOLOGY (yellow dart)
now you can select your Radio Access Technology
select - (1) NB1
or (2) CAT-M1
or (3) GSM
- In this case we selected (1) NB1 (orange dart)
- New radio Access technology is now selected (red square) - to return to MAIN MENU press ECS or press Disconnect and unplug the USB cable.
- Done with setting radio access technology.