Settings at NB IoT Clima 29-0409

You need:


To change the sensor stetting see the following steps:

Depending on which sensor is connectet to SENS-1 or SENS-2 the Type has to be changed in the Sensor Settings via the Terminal Program

  1. Start the PI Service terminal program. 
  2. Connect the PC and the motherboard (PCB) with the USB cable (yellow square below).
  3. Connect the battery to the main board (red square below)   
  4. Select the correct Serial Port an click on "Connect"
    If it is the only one device connected to your PC, COM port is detected automatically.  When connecting for the first time, the PC installs the driver for the board (internet connection of the PC required)
  5. Press H to open the menu 


  6. To see the Sensor Settings
    press
  7. (C) Sensor settings (red dart)
    then which Sensor type you want to change
  8. (3) Sensor type on SENS-1 (blue dart) 
    or (4) Sensor type on SENS-2 (yellow dart)

  9. In this case we select (3) Sensor type on SENS-1
    Here you can see the current sensor type (marked with a red square)
  10. Select the new Sensor type (in this case PI54D-orange dart)
    press
  11. (15) and then (ENTER)
  12. New sensor is now selected - to return to MAIN MENU press ECS or press Disconnect and unplug the USB cable.
  13. Done with Sensor setting.
  14. Here you see an image where you can see which Sensor type is used for which Sensor:


To change the the RADIO ACCESS TECHNOLOGY see the following steps:


  1. Start the PI Service terminal program. 
  2. Connect the PC and the motherboard (PCB) with the USB cable (yellow square below).
  3. Connect the battery to the main board (red square below)   
  4. Select the correct Serial Port an click on "Connect"
    If it is the only one device connected to your PC, COM port is detected automatically.  When connecting for the first time, the PC installs the driver for the board (internet connection of the PC required)
  5. Press H to open the menu 


  6. To see the Radio Access Technology
    press
  7. (P) Setup NBIoT module parameters (blue dart)
    Here you see the current Radio Access Technology (pink square)

    to change it 
    press 
  8. (8) RADIO ACCESS TECHNOLOGY (yellow dart) 
    now you can select your Radio Access Technology

    select
  9. (1) NB1 
    or (2) CAT-M1
    or (3) GSM
     
  10. In this case we selected (1) NB1 (orange dart)
  11. New radio Access technology is now selected (red square)  - to return to MAIN MENU press ECS or press Disconnect and unplug the USB cable.
  12. Done with setting radio access technology.