iMETOS 3.3, ECO D3, µMETOS Clima and Soil NB-IoT & LoRa

Order Number: 900139

STAGEMINIMUM VOLTAGESENSOR MEASUREMENTSDATA TRANSMISSIONNOTE
1. normal mode> 6 Vdefault (normal) operating mode
where the device measures and logs
sensors data and transmits the logs
to the FieldClimate cloud
2. gathering mode5.8 V – 6 Vdevice is only measuring and logging
sensors data, it does not have
enough power to execute
transmission
3. Sleeping mode< 5.8 Vdevice does not have enough power
to measure the sensors or to do the
data transmissions


nMETOS, LoRAIN, LoRATH


a. Supercapacitor board number 29-0410


Supported on nMETOS boards Rev. C and E only.


Wiring diagram:

The battery goes plugged into BAT input on the super capacitor board 29-0410

Super capacitor is plugged into SCAP input on the nMETOS board

Solar panel is plugged into SOL input on the nMETOS board


29-0410 chart display:



b. Supercapacitor board number 29-0370 (discontinued):


Supported on nMETOS boards Rev. B, C and E.


Solar panel goes plugged into SOL input on the super capacitor board 29-0370

Super capacitor is plugged into SCAL input on the nMETOS board

29-0370 chart display:



IMPORTANT:

DO NOT USE install the solar panel without a super capacitor on the nMETOS/LoRAIN with a battery. The battery FANSO and SAFT ARE NOT rechargeable.



INFORMATION about PCB REVISION:

Please, refer to Check the version (revision) of the board 29-0404


HOW TO MEASURE THE BATTERY CHARGE:


iMETOS 3.3, ECO D3, µMETOS Clima and Soil NB-IoT & LoRa


a. Using a multimeter:


b. Menu of the device:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal iMetos 3.3 & ECO D3


On the main, select (2) SENSORS and then (B) BATTERY STATUS:


NOTE: Ensure the battery is above 6.3V.


nMETOS, LoRAIN, LoRATH


a. Multimeter:



b. Menu of the device:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal NB-IoT Stations


 On the main menu, select (5) SENSOR TESTING:


NOTE: Ensure the battery has 3.5 or 3.6V and the supercapacitor 2.5V or more. If the battery or the supercapacitor are below the threshold, it is not recommended to use them.