Batteries and Supercapacitors User Guide

Modified on Mon, 24 Mar at 4:29 PM

iMETOS 3.3, ECO D3, µMETOS Clima and Soil NB-IoT & LoRa

Order Number: 900139

STAGEMINIMUM VOLTAGESENSOR MEASUREMENTSDATA TRANSMISSIONNOTE
1. normal mode> 6 Vdefault (normal) operating mode
where the device measures and logs
sensors data and transmits the logs
to the FieldClimate cloud
2. gathering mode5.8 V – 6 Vdevice is only measuring and logging
sensors data, it does not have
enough power to execute
transmission
3. Sleeping mode< 5.8 Vdevice does not have enough power
to measure the sensors or to do the
data transmissions


nMETOS, LoRAIN, LoRATH


a. Supercapacitor board number 29-0410


Supported on nMETOS boards Rev. C and E only.


Wiring diagram:

The battery goes plugged into BAT input on the super capacitor board 29-0410

Super capacitor is plugged into SCAP input on the nMETOS board

Solar panel is plugged into SOL input on the nMETOS board


29-0410 chart display:



b. Supercapacitor board number 29-0370 (discontinued):


Supported on nMETOS boards Rev. B, C and E.


Solar panel goes plugged into SOL input on the super capacitor board 29-0370

Super capacitor is plugged into SCAL input on the nMETOS board

29-0370 chart display:



IMPORTANT:

DO NOT USE install the solar panel without a super capacitor on the nMETOS/LoRAIN with a battery. The battery FANSO and SAFT ARE NOT rechargeable.



INFORMATION about PCB REVISION:

Please, refer to Check the version (revision) of the board 29-0404


HOW TO MEASURE THE BATTERY CHARGE:


iMETOS 3.3, ECO D3, µMETOS Clima and Soil NB-IoT & LoRa


a. Using a multimeter:


b. Menu of the device:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal iMetos 3.3 & ECO D3


On the main, select (2) SENSORS and then (B) BATTERY STATUS:


NOTE: Ensure the battery is above 6.3V.


nMETOS, LoRAIN, LoRATH


a. Multimeter:



b. Menu of the device:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal NB-IoT Stations


 On the main menu, select (5) SENSOR TESTING:


NOTE: Ensure the battery has 3.5 or 3.6V and the supercapacitor 2.5V or more. If the battery or the supercapacitor are below the threshold, it is not recommended to use them.



Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article