Battery for:
  • iMetos 3.3
  • iMetos ECO 
  • µMetos NB-IoT
  • µMetos Soil LoRa
  • µMetos Clima LoRa

Order Number: 900139  

STAGEMINIMUM VOLTAGESENSOR MEASUREMENTSDATA TRANSMISSIONNOTE
1. normal mode> 6 Vdefault (normal) operating mode
where the device measures and logs
sensors data and transmits the logs
to the FieldClimate cloud
2. gathering mode5.8 V – 6 Vdevice is only measuring and logging
sensors data, it does not have
enough power to execute
transmission
3. Sleeping mode< 5.8 V
device does not have enough power
to measure the sensors or to do the
data transmissions


How to measure the battery level


a. Using a multi tester:


b. by accessing the menu:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal iMetos 3.3 & ECO D3


On the main, select (2) SENSORS and then (B) BATTERY STATUS


Notes:

The battery must have more than 6V or 6000mV. 6.4V or 6400 mV is preferrable.


Battery for:

  • nMetos80
  • nMetos100+
  • LoRAIN NB-IoT
  • LoRAIN LoRaWAN
  • LoRAIN Soil NB-IoT
  • LoRAIN Soil LoRaWAN
  • LoRATH NB-IoT
  • LoRATH LoRaWAN
  • LoRATH Soil NB-IoT
  • LoRATH Soil LoRaWAN 



How to measure the battery level:


a. Using a multi tester:

b. By accessing the menu:

To know how to connect to the station using a USB cable, please, refer to: Create Log file with PI Service Terminal NB-IoT Stations


 On the main, select (5) SENSOR TESTING:


The battery must have more than 3.6V or 3600mB.